Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 6006 guests and 
3 members online.
Categories
Information
Featured Product
Home >> CANON >> IR1600 Service Manual
 
 0 item(s) in your cart 

CANON IR1600
Service Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Contains Circuit Diagrams
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of CANON IR1600 Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagrams, printed circuit boards, repair tips, wiring diagrams, block diagrams and parts list. Service Manual ( sometimes called Repair Manual ) is used mainly by technicians.

If You just want to know how to use Your tv, video, mp3 player etc. You should look for Owner's Manual. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 SIX SANSUI Service Manual by joe kosik;
Print was clear and easy to read. Thank you Joe joeoldaudio
 M9420 TELEFUNKEN Service Manual by Jürgen Waschke;
Very great deal. In a few minutes a have the manual, that I needed. Thanl you very much
 KA994 KENWOOD Service Manual by mike powers;
Manual was complete. Received it quickly. No problems
 RS-736US PANASONIC Service Manual by mike powers;
Product was very good. Received quickly and complete
 AV-3600 SONY Service Manual by David Niccum;
The Sony AV-3600 service manual was what I needed for the repair of this unit Thanks for the good service Dave

Text excerpt from page 194 (click to view)
CHAPTER 7 FIXING SYSTEM

2.4 Protective Mechanism
The machine is equipped with the following protective mechanisms used to prevent malfunction of the fixing heater: 1.Thermistor High Temperature The ASIC and the high temperature detection circuit on the DC controller monitor the voltage readings of the main thermistor and sub thermistor; if the main thermistor detects a voltage equivalent of the following temperature, the CPU will identify the condition as indicating overheating. � 220°C or higher (read by main thermistor TH101) 2. Thermistor Disconnection The connector detection circuit on the DC controller PCB monitors the THCNCT signal, and the CPU will assume that the connector of the thermistor is disconnected if the signal is �0�. 3. Cutting Off the Power in Response to Overheating (as detected by the thermal switch) If the internal temperature of the thermal switch (THSW101) exceeds about 230°C, the thermal switch will go OFF to cut the power to the fixing heater. 4. Detecting the Activation of the Fixing Heater The fixing heater detection circuit on the power supply PCB causes the HEATDT* signal to go �0� if the FSRDRV* signal is �0� (fixing heater ON). As such, the ASIC will assume that the fixing heater activation is faulty (triac short circuit) if the HEATDT* signal goes �1�.

7-10

COPYRIGHT© 2001 CANON INC. 2000 CANON iR1600/iR2000 REV.0 SEPT. 2001

You might also want to buy

$4.99

IR1600 CANON
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

IR1600 CANON
Parts Catalog

Parts Catalog only. It's available in PDF format. Useful, if Your equipment is broken and You need t…
>
Parse Time: 0.304 - Number of Queries: 114 - Query Time: 0.079